Difference between revisions of "MCE firmware"
From MCEWiki
(→Development Tools) |
|||
Line 1: | Line 1: | ||
= Critical Notes = | = Critical Notes = | ||
− | * | + | * In v5+ firmware, if you update firmware on any readout card, the card doesn't reply to any command unless the Clock Card is also reprogrammed. |
− | * Always cleanly reset the MCE after a power-up or a reconfiguration! If not, MCE communication with the PC or Sync Box may not work. | + | * Always cleanly reset the MCE after a power-up or a reconfiguration! If not, MCE communication with the PC or Sync Box may not work. On MAS prompt, type: '''''mce_reset_clean''''' |
− | |||
− | * After an mce_reset, not all of the DAC outputs are set to zero. In addition, values written to RAM-based registers are not reset. A full reconfiguration is required for a proper reset. You may power-cycle the MCE remotely if the MCE is equipped with a PSA (UBC switching supply) by issuing | + | * After an mce_reset, not all of the DAC outputs are set to zero. In addition, values written to RAM-based registers are not reset. A full reconfiguration is required for a proper reset. You may power-cycle the MCE remotely if the MCE is equipped with a PSA (UBC switching supply) by issuing '''''mce_cmd -x rs psc cycle_pow 1''''' and then '''''mce_reset_clean''''' |
− | |||
− | |||
− | |||
= Releases = | = Releases = | ||
All firmware can be downloaded [http://www.phas.ubc.ca/~mce/mcedocs/firmware/ here] | All firmware can be downloaded [http://www.phas.ubc.ca/~mce/mcedocs/firmware/ here] | ||
+ | |||
Release notes for each firmware release can be found below: | Release notes for each firmware release can be found below: | ||
* [[ Clock Card (CC) ]] | * [[ Clock Card (CC) ]] |
Revision as of 15:49, 14 September 2010
Contents
Critical Notes
- In v5+ firmware, if you update firmware on any readout card, the card doesn't reply to any command unless the Clock Card is also reprogrammed.
- Always cleanly reset the MCE after a power-up or a reconfiguration! If not, MCE communication with the PC or Sync Box may not work. On MAS prompt, type: mce_reset_clean
- After an mce_reset, not all of the DAC outputs are set to zero. In addition, values written to RAM-based registers are not reset. A full reconfiguration is required for a proper reset. You may power-cycle the MCE remotely if the MCE is equipped with a PSA (UBC switching supply) by issuing mce_cmd -x rs psc cycle_pow 1 and then mce_reset_clean
Releases
All firmware can be downloaded here
Release notes for each firmware release can be found below:
- Clock Card (CC)
- Readout Card (RC) Rev. A/B (Stratix I)
- Readout Card (RC) Rev. C/D (Stratix III)
- Bias Card (BC)
- Address Card (AC)
- Power-Supply Unit Controller (PSUC) Rev. 1
- Power-Supply Unit Controller (PSUC) Rev. 2
- Sync Box Firmware
- Compatible Versions (CC,RC,BC,AC) . (Lists of versions of firmware to use together.)
Firmware Upgrade Methods
- Using Altera supplied Hardware/Software
- Remote firmware update over the MCE fibre interface
- Firmware Downloads and .Jam-File Generation
- Generating .JAM Files For Remote Update
- Sof2jam (bash script)
- Generating .Jam-Files Manually
CVS Repository
- Ask the "MCE team at UBC" for a username/password to be able to access the repository
- Install a CVS client ( e.g. http://www.tortoisecvs.org/ )
- CVS server info is:
- server: e-mode.phas.ubc.ca
- repository folder:/home/cvsroot/mce
- module name: mce
- protocol: pserver
MCE Features and How-To Guides
- MCE Commands
- Upgrading From 4.x.x To 5.x.x Firmware -- using SCUBA-2 as an example
- Data Acquisition
- Fast Data Acquisition -- i.e. up to the frame rate
- The STOP Command (CC v4.0.b, v4.0.c, v5.0.1+)
- How to Configure Which Readout Cards Report Data (CC v4.0.a+)
- How to Read a Column at the Frame Rate (CC v5.0.0 & RC v5.0.0+)
- Rectangle Mode Data (CC v5.0.0 & RC v5.0.1+)
- Readout Card
- Data Modes
- Filtered Data & the Digital 4-pole Butterworth Low-pass Filter
- Raw 50 MHz Data
- Flux Jumping
- FSFB Clamping Commands -- to prevent unlocked pixels from ramping (RC v5.0.a+)
- FSFB Servo Start Value
- Clock Card
- Remote Firmware Update (CC v5.0.7+)
- Internal Commands
- Arbitrary Waveform Generator -- for maximum length sequences and complex impedance measurements (CC v5.0.3+)
- Ramp Generator
- Temperature monitoring
MCE Firmware Bugs/ Features Under Development has been moved to the Internal MCE Wiki Bug List.
Firmware Development Tools
- Quartus II Installation
- ModelSim SE Installation (from scratch)
- CVS Firmware Repository
- JAM Player
- JRunner
- SVN links (We decided (sadly) NOT to migrate from CVS to SVN, if we ever do here is some information:)
- SVN Manual
- Accessing the SVN Repository
- SVN Commit Guidelines
- SVN Basic Operations