Difference between revisions of "Recommended firmware versions"

From MCEWiki
(SCUBA-2)
 
(38 intermediate revisions by 6 users not shown)
Line 1: Line 1:
 +
{{Related|Firmware}}
 
Each card type in the MCE has many versions of firmware available for it.  Certain versions of firmware are not compatible with those on other types of cards.  The following is a list of firmware groups that are compatible with each other:
 
Each card type in the MCE has many versions of firmware available for it.  Certain versions of firmware are not compatible with those on other types of cards.  The following is a list of firmware groups that are compatible with each other:
  
= Latest Release for Experimental Use =
+
== Recommended Releases (Version 5) ==
* As of 4 June 2009
+
As of 2017:
** cc_v05000002
+
*'''[[Clock Card firmware|CC]]''': [[Clock Card firmware#Revision 5.0.e (stable)|5.0.E]] (15 May, 2012)
** rc_v05000002 (raw data + filtered data + rectangle mode)
+
*'''[[Readout Card firmware|RC]]''':
** bc_v05000000
+
**''For Rev. E  cards'': [[Readout Card firmware#Revision 5.1.d|5.1.D]] (30 October, 2012)
** ac_v05000000
+
**''For Rev. B  cards'': [[Readout Card firmware#Revision 5.1.b (Stable Rev.B Cards)|5.1.B]] (23 March, 2012)
 +
*'''[[Bias Card firmware|BC]]''': [[Bias Card firmware#Revision 5.3.4 (recommended)|5.3.4]] (20 December, 2012)
 +
*'''[[Address Card firmware|AC]]''': [[Address Card firmware#Revision 5.0.4 (Stable)|5.0.4]] (16 February, 2010)
  
= Latest Stable Release for Telescope Use =
+
== Firmware Files and Descriptions ==
* As of 4 June 2009
 
** cc_v04000009
 
** rc_v0400000e (raw data + filtered data)
 
** bc_v01040002
 
** ac_v02000007
 
 
 
= CalTech =
 
* As of 23 April 2009
 
** cc_v05000002
 
** rc_v05000002 (raw data + filtered data + rectangle mode)
 
** bc_v05000000
 
** ac_v05000000
 
 
 
= ACT =
 
* As of 23 April 2009
 
** cc_v
 
** rc_v0400000c
 
** bc_v
 
** ac_v
 
 
 
= SCUBA-2 =
 
* As of 4 June 2009
 
** cc_v04000009
 
** rc_v04000001
 
** bc_v01030007
 
** ac_v02000003
 
 
 
= Firmware Files and Descriptions =
 
 
Firmware files are available here:
 
Firmware files are available here:
* http://www.phas.ubc.ca/~mce/mcedocs/firmware/
+
* http://e-mode.phas.ubc.ca/mce_firmware/
  
 
Firmware descriptions are available here
 
Firmware descriptions are available here
* [[ Clock Card (CC) ]]
+
* [[ Clock Card firmware ]]
* [[ Readout Card (RC) | Readout Card (RC) Rev. A/B]]
+
* [[ Readout Card firmware]]
* [[ Readout Card (RC) Rev. C ]]
+
* [[ Bias Card firmware]]
* [[ Bias Card (BC) ]]
+
* [[ Address Card firmware]]
* [[ Address Card (AC) ]]
+
 
 +
[[Category:Address Card Firmware]]
 +
[[Category:Bias Card Firmware]]
 +
[[Category:Clock Card Firmware]]
 +
[[Category:Readout Card Firmware]]

Latest revision as of 15:22, 22 March 2018

Related topics:

Each card type in the MCE has many versions of firmware available for it. Certain versions of firmware are not compatible with those on other types of cards. The following is a list of firmware groups that are compatible with each other:

Recommended Releases (Version 5)

As of 2017:

  • CC: 5.0.E (15 May, 2012)
  • RC:
    • For Rev. E cards: 5.1.D (30 October, 2012)
    • For Rev. B cards: 5.1.B (23 March, 2012)
  • BC: 5.3.4 (20 December, 2012)
  • AC: 5.0.4 (16 February, 2010)

Firmware Files and Descriptions

Firmware files are available here:

Firmware descriptions are available here