Difference between revisions of "Vicor Power Assembly"
From MCEWiki
Line 14: | Line 14: | ||
: Vcore: 2.9 to 3.2 V | : Vcore: 2.9 to 3.2 V | ||
− | ; | + | ; Power: 100W |
; Regulated: Yes | ; Regulated: Yes |
Revision as of 19:13, 7 March 2018
Related topics:
► Hardware
The MCE can be equipped with a 24V DC-in or 48V DC-in switching supply designed for use in balloon-based experiments. This unit contains a set of Vicor DC-DC converters that are trimmed to accommodate losses from cables of up to 2-metres, so they can be located up to 2-m away from the actual MCE subrack.
Specification
- DC Input Type
- 24V (18-36V) - Rev. C, Issues 1, 2, 5, 6
- 48V (36-60V) - Rev. C, Issues 3, 4, 7
- 3A at 24V to power one 3-MDM MCE48 crate (6A for two)
- DC output
- pVa: 6.1 to 6.3 V
- nVa: -6.1 to -6.3 V
- Vlvd: 4.4 to 4.7 V
- Vcore: 2.9 to 3.2 V
- Power
- 100W
- Regulated
- Yes
- Efficiency
- 75%
- Dimensions (L x W x H)
- 24cm x 20cm x 5cm
- Weight
- < 2kg and a 1-m power cable is ~1kg
Connectors
- Input
- Writing harness: PDF
- Connector: Amphenol PTC-2A-14-5P
- Output
Mechanical Drawings
- Assembled Box: MEC-C585-416D
- Box Lid: MEC-C585-405D
- Unfolded Box: MEC-C585-404D
- Mounting Flange: MEC-C585-406B
Cooling
For Spider, the mounting/heat extraction block is bolted to a heat exchanger through which the 4He blow-off from the cryostat's vapour-cooled shield is vented.