= All Card Commands = | = All Card Commands = | ||
+ | * These commands can be issued to any card in the MCE (cc, rc1 to rc4, bc1, bc2, bc3, ac), except the Power Supply Card. Dark-shaded rows indicate commands that remain to be implemented as of 16 May 2008. | ||
+ | |||
= System Commands = | = System Commands = | ||
= Clock Card Commands = | = Clock Card Commands = |
Revision as of 18:52, 20 January 2010
Contents
All Card Commands
- These commands can be issued to any card in the MCE (cc, rc1 to rc4, bc1, bc2, bc3, ac), except the Power Supply Card. Dark-shaded rows indicate commands that remain to be implemented as of 16 May 2008.
System Commands
Clock Card Commands
Readout Card Commands
Bias Card Commands
Address Card Commands
Parameter ID | Physical Address | Type | Firmware Revision | Parameters | Description |
---|---|---|---|---|---|
-- | 0x00 | -- | -- | -- | Reserved |
row_order | 0x01 | wb/rb | all | row1,
row2, ... |
This command is relevant when enbl_mux = 1 or 2. Read/write the row-addressing order. A sequence of up to 41 rows is specified at once. The row numbers that are specified with this command refer to the physical channel numbers on the Address Card. Note: After this command is issued, a “flx_lp_init” command must be issued to all the readout cards to discard previous PID-loop calculations and to clean out the rest of the data pipeline. Default = 0,0,0,… |