Difference between revisions of "MCE commands"

From MCEWiki
(Address Card (ac) Commands)
Line 1: Line 1:
= All Card (cc/rc#/bc#/ac) Commands =
+
= All Card Commands =
= System (sys) Commands =
+
= System Commands =
= Clock Card (cc) Commands =
+
= Clock Card Commands =
= Readout Card (rc#) Commands =
+
= Readout Card Commands =
= Bias Card (bc#) Commands =
+
= Bias Card Commands =
= Address Card (ac) Commands =
+
= Address Card Commands =
  
 
{| border="1"
 
{| border="1"

Revision as of 18:51, 20 January 2010

All Card Commands

System Commands

Clock Card Commands

Readout Card Commands

Bias Card Commands

Address Card Commands

Parameter ID Physical Address Type Firmware Revision Parameters Description
-- 0x00 -- -- -- Reserved
row_order 0x01 wb/rb all row1,

row2, ...

This command is relevant when enbl_mux = 1 or 2. Read/write the row-addressing order. A sequence of up to 41 rows is specified at once. The row numbers that are specified with this command refer to the physical channel numbers on the Address Card. Note: After this command is issued, a “flx_lp_init” command must be issued to all the readout cards to discard previous PID-loop calculations and to clean out the rest of the data pipeline. Default = 0,0,0,…