Sync Box AC-in Rack Mount I/O

From MCEWiki
Related topics:
ACDCU(0-7)
8 TTL outputs. Carries a high/low signal that enables/disables the MCE AC/DC converter.
MCE(0-7)
8 Fibre outputs. Carries a 50 MHz Manchester-encoded signal containing data packets, which include incremented sequence numbers. Programmable as two sets of 4 outputs with differently spaced data packets on each.
RTS-DV
differential RS485 input. Detects falling edges from a Real-Time Sequencer (implemented by SCUBA2) which tells the Sync box when to tell the MCE's to collect data.
OPTO-TTL
TTL input, spare input to the command processor. ***Not currently used, and open for suggestions.
RS232 RxTx
TTL input and output, used to command the Sync Box from a PC.
DV Spare 1
differential RS485 output. Carries a 5 MHz clock signal that is synchronous with DV Spare 2. Now called Data Sync 2
DV Spare 2
differential RS485 output. Carries a 5 MHz data signal that is synchronized with DV Spare 1, and contains the same sequence numbers as the MCE(0-7) outputs. NOTE: This output only contains the DV info stream, but not the occurrences of Addr_Zero between DVs. Now called Data Sync 1
Polarimeter
output, available both as TTL and differential RS485, asserted for 1us on an Address-Return-to-Zero(ARZ) if a DV pulse is detected since the last ARZ. Now called Data Sync 4 and in firmware Rev 21, this output is duplicate of DV_Spare2 or 5MHz clock.
FTS
output, available both as TTL and differential RS485, asserted for 1us on an Address-Return-to-Zero(ARZ) if a DV pulse is detected since the last ARZ. Now called Data Sync 3 and in firmware Rev 21, this output is duplicate of DV_Spare1 or 5MHz data-stream.
TTL-IN
SMB TTL input, spare input to the FPGA.
TTL-OUT
SMB TTL output. Carries a 50 MHz clock signal.
Power
47–440Hz, 85–265VAC mains power over a 3-pin HP-style power connector.

Signal Translation table between Rack-mount and DC-in versions of Sync Box

AC-in DC-in
DV_Spare1 data_sync1
DV_Spare2 data_sync2
DV_OUT_FTS data_sync4
DV_OUT_POL data_sync3

WARNING: signal polarity may be swapped on data_sync1 and data_sync2.

Schematics