Clock Card Rev B5 to Rev B6 changes

From MCEWiki
  • ECO-044-20110314
  • Module Name: Clock card
  • Change From: Rev. B Issue 5
  • Change To: Rev. B Issue 6
  • Change Request # Email 12-10-2007
  • Impacted Module # (revision & issue) CC rev. B Issue 5
  • Requested by: Tom Felton
  • Date: Mar. 14, 2011

Problem Description

There are some parts that are not used and there is no intention to use them, e.g., real-time clock circuitry (U51, BT1, c181, R198, R199, Socket 4), test mictors for fibre interface (P4), extra test header (P10), slow-dv input (U23). The last one has only led to confusion in the past as people would plug in the Manchester encoded input in the non encoded input. (U23).

Change Description for problem

Do Not Populate the following components: P10, P4, U23, U51, BT1, R198, R199, C181, Socket 4.