Difference between revisions of "Test plans"

From MCEWiki
 
Line 1: Line 1:
 +
use 2-slot backplane and set slot-id dip switch to 1011 (0xB) otherwise rc1 replies do not come back, because the card is not identified properly.
 
firmware located www.phas.ubc.ca/~mce/mcedocs/firmware
 
firmware located www.phas.ubc.ca/~mce/mcedocs/firmware
 
CC firmware 5.0.7
 
CC firmware 5.0.7
 
RC firmware rc_stratix3_5.0.6_jan11_2010
 
RC firmware rc_stratix3_5.0.6_jan11_2010
 +
program both cards
  
 +
# To make sure both cards communicate:
 +
  mce_cmd -x rb cc fw_rev
 +
 +
and you will see:
 +
  Line  0 : ok : 0x5000007
 +
 +
and then type:
 +
  mce_cmd -x rb rc1 fw_rev
 +
and you will see
 +
  Line  0 : ok : 0xffff0006
 
run card_all_test
 
run card_all_test
 
run rc_test
 
run rc_test
  
 
log results
 
log results

Revision as of 11:20, 29 September 2010

use 2-slot backplane and set slot-id dip switch to 1011 (0xB) otherwise rc1 replies do not come back, because the card is not identified properly. firmware located www.phas.ubc.ca/~mce/mcedocs/firmware CC firmware 5.0.7 RC firmware rc_stratix3_5.0.6_jan11_2010 program both cards

  1. To make sure both cards communicate:
 mce_cmd -x rb cc fw_rev

and you will see:

 Line   0 : ok : 0x5000007

and then type:

 mce_cmd -x rb rc1 fw_rev

and you will see

 Line   0 : ok : 0xffff0006

run card_all_test run rc_test

log results