Vicor Power Assembly
From MCEWiki
Template:Hierarchy header The MCE can alternatively be equipped with a 18–36Vin (24Vin nominal) switching supply designed for use in balloon-based experiments. The Vicor supplies are trimmed to accomodate losses of up to 2m cable, so they can be located up to 2m away from the actual MCE crate.
Contents
Schematics
- Schematics for the Vicor Supplies can be found here
- The schematics for the Wiring harness in the box and the pinout for the Winchester connector: pdf
Check the schematics for Input/Output connector pinout.
- Output Connector
- Winchester MRA34SG
- Input Connector
- Amphenol PTC-2A-14-5P
Specification
- DC Input Type
- 18-36V
- 3A from 24V to power one 3-MDM MCE48 crate (6A for two)
- DC output
- pVa: 6.1 to 6.3 V
- nVa: -6.1 to -6.3 V
- Vlvd: 4.4 to 4.7 V
- Vcore: 2.9 to 3.2 V
- Watts
- 100W
- Regulated
- Yes
- Efficiency
- 75%
- Dimensions (L x W x H)
- 24cm x 20cm x 5cm
- Weight
- < 2kg and a 1m power cable is ~1kg
Notes
- The Vicor supply is equipped with two Winchester connectors to power two MCE48 crates. So far, we are able to use a Y cable and power two MCE48 from one connector. When we tried to use each connector separately, with separate cables, oddly enough, the noise performance was degraded.
- We have not used the Vicor supply to power a 5-MDM MCE72 yet. The power requirements for a 5-MDM MCE are disctributed slightly differently than twice an MCE48 mainly due to LN_BIAS circutries.