  • As of Clock Card firmware Rev. 5.0.0, the Clock Card has the ability to return data from any permutation of Readout Cards.
  • The command to use is called rcs_to_report_data. The parameter to pass with it is broken down into 9 bits:
    • Bit 9: --
    • Bit 8: --
    • Bit 7: --
    • Bit 6: --
    • Bit 5: Readout Card 1
    • Bit 4: Readout Card 2
    • Bit 3: Readout Card 3
    • Bit 2: Readout Card 4
    • Bit 1: --
    • Bit 0: --
  • It applies only to Readout Cards, and only for data taking (ret_dat) commands. It's register sets which Readout Cards return data during a data run. This command allows the selective return of data without affecting which cards respond to all other commands, which is useful if a data run fails.
  • The readout_cards_to_report_data bits are encapsulated in the header of every data packet returned to the PC. They are stored at word index 0, bits 15:6. The inclusion of these two fields allows software to do processing on binary data files without having to read the .run file associated with it.
  • The data-size field of the data packet will reflect the actual size of the data packet being returned. The data size of the packet is determined using the following calculation:
data_size = num_rcs_returning_data * num_rows_reported * num_cols_reported
  • The full packet size of a data packet (returned in word 4 of a data packet) is thus:
packet_size = data_size + header_size(=43) + checksum_size(=1)
  • For more information on the data header, see the document discussing MCE File Formats.