Latest revision as of 16:15, 31 August 2016
We have built a passive cooling system for the MCEs used in balloon-based experiments. Fins are inserted between the cards and heat transported from the fins to a heat-extraction flange via heat pipes. On the Spider gondola, the heat-extraction flange is bolted directly to the cryostat wall, which provides a sufficiently large radiating surface to cool its (48 HP) subracks.
Here are some pictures of MCE flight hardware