Difference between revisions of "MCE Cooling for balloon-based experiments"

From MCEWiki
Line 2: Line 2:
  
 
Here are some [http://www.phas.ubc.ca/%7Emce/mcedocs/pics/mce_flight_hardware/index.html pictures of MCE flight hardware]
 
Here are some [http://www.phas.ubc.ca/%7Emce/mcedocs/pics/mce_flight_hardware/index.html pictures of MCE flight hardware]
 +
 +
Here is a snapshot of the solidworks model [http://www.phas.ubc.ca/%7Emce/mcedocs/pics/mce_flight_hardware/2014-10-24%2048HP%20Subrack%20with%20cooling%20(M12-017).PNG 48HP Subrack with cooling]

Revision as of 13:43, 24 October 2014

We have built a passive cooling system for the MCEs used in balloon-based experiments. Fins are inserted between the cards and heat transported from the fins to a heat-extraction flange via heat pipes. On the Spider gondola, the heat-extraction flange is bolted directly to the cryostat wall, which provides a sufficiently large radiating surface to cool its (48 HP) subracks.

Here are some pictures of MCE flight hardware

Here is a snapshot of the solidworks model 48HP Subrack with cooling