Difference between revisions of "Vicor Power Assembly"

From MCEWiki
(Schematics)
Line 24: Line 24:
  
 
=== Schematics ===
 
=== Schematics ===
* Schematics for the Vicor Supplies can be found:
+
* Schematics for the Vicor Supplies: [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE_C585-401_RevC2_VicorPSU_Schematics.pdf (+24V input - Rev C2 [PDF])] [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE_C585-401_RevC3_VicorPSU_Schematics.pdf (Custom +48V input-Rev C3 [PDF])]
** [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE_C585-401_RevC2_VicorPSU_Schematics.pdf Rev C2]  
 
 
 
** [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE_C585-401_RevC3_VicorPSU_Schematics.pdf Custom +48V input-Rev C3]
 
 
* The schematics for the Wiring harness in the box and the pinout for the Winchester connector: [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE-C584-402_RevA_Wiring_Harness.pdf pdf]
 
* The schematics for the Wiring harness in the box and the pinout for the Winchester connector: [http://www.phas.ubc.ca/~mce/mcedocs/hardware/schematics/PowerSupplyVicor/ELE-C584-402_RevA_Wiring_Harness.pdf pdf]
  

Revision as of 13:16, 5 May 2014

Template:Hierarchy header The MCE can be equipped with a 18–36Vin (24Vin nominal) switching supply designed for use in balloon-based experiments. This unit contains a set of Vicor DC-DC converters that are trimmed to accomodate losses of up to 2m cable, so they can be located up to 2m away from the actual MCE crate.

Specification

DC Input Type
18-36V
3A from 24V to power one 3-MDM MCE48 crate (6A for two)
DC output
pVa: 6.1 to 6.3 V
nVa: -6.1 to -6.3 V
Vlvd: 4.4 to 4.7 V
Vcore: 2.9 to 3.2 V
Watts
100W
Regulated
Yes
Efficiency
75%
Dimensions (L x W x H)
24cm x 20cm x 5cm
Weight
< 2kg and a 1m power cable is ~1kg

Schematics

Check the schematics for Input/Output connector pinout.

Output Connector
Winchester MRA34SG
Input Connector
Amphenol PTC-2A-14-5P

Mechanical Drawings

Mechanical Drawings for Vicor Aluminum Box RevC

Notes

  1. The Vicor supply is equipped with two Winchester connectors to power two MCE48 crates. So far, we are able to use a Y cable and power two MCE48 from one connector. When we tried to use each connector separately, with separate cables, oddly enough, the noise performance was degraded.
  2. We have not used the Vicor supply to power a 5-MDM MCE72 yet. The power requirements for a 5-MDM MCE are disctributed slightly differently than twice an MCE48 mainly due to LN_BIAS circutries.

Cooling

For Spider, the mounting/heat extraction block is bolted to a heat exchanger through which the 4He blow-off from the cryostat's vapour-cooled shield is vented.

Photos

Testing