Difference between revisions of "Cryocable Impedance"
From MCEWiki
Line 12: | Line 12: | ||
:test cryostat cryo cable: 48" + 43" long, R~90 ohms (round trip) and C~180 pF between pairs | :test cryostat cryo cable: 48" + 43" long, R~90 ohms (round trip) and C~180 pF between pairs | ||
:Flight cryostat cryo cable: 3m + 45" long, R~160 ohm (round trip) and C~350pF between pairs. | :Flight cryostat cryo cable: 3m + 45" long, R~160 ohm (round trip) and C~350pF between pairs. | ||
+ | |||
+ | ;HAWC | ||
+ | : R~146 ohm, C~350 pF for RC=51 ns | ||
== == | == == | ||
back to [[Filter Box]] | back to [[Filter Box]] |
Revision as of 12:18, 8 March 2014
- Generally
- 30-50pF per meter (typically <2m)
- 265-Ohm, 190-Ohm, 110-Ohm (quoted from various experiments)
- SCUBA-2
- 190-Ohm, 50-pf(?) single wire
- ssa-outputs use wires with twice the diameter => 190/4=47.5 Ohm
- ACT
- ~190 ohm
- Spider
- test cryostat cryo cable: 48" + 43" long, R~90 ohms (round trip) and C~180 pF between pairs
- Flight cryostat cryo cable: 3m + 45" long, R~160 ohm (round trip) and C~350pF between pairs.
- HAWC
- R~146 ohm, C~350 pF for RC=51 ns
back to Filter Box