Difference between revisions of "Subrack"
From MCEWiki
(→Dimensions and Weight) |
|||
Line 5: | Line 5: | ||
An intermediate sized 60-HP subrack was also prototyped but not produced in large numbers. Functionally it is equivalent to the modern 48-HP subrack. | An intermediate sized 60-HP subrack was also prototyped but not produced in large numbers. Functionally it is equivalent to the modern 48-HP subrack. | ||
+ | |||
+ | [http://en.wikipedia.org/wiki/Horizontal_pitch (what is HP?)] | ||
== Components == | == Components == | ||
Line 25: | Line 27: | ||
* A fully populated 3-MDM MCE weighs 9.5 kg | * A fully populated 3-MDM MCE weighs 9.5 kg | ||
* Dimensions for a 48-HP MCE: ~ 40cm x 31cm x 34cm (L x W x H) | * Dimensions for a 48-HP MCE: ~ 40cm x 31cm x 34cm (L x W x H) | ||
+ | ** [http://www.phas.ubc.ca/~mce/mcedocs/overview/MEC-C580-111_48HP_Subrack_Mounting.pdf MCE 48-HP Mounting Dimensions (PDF)] | ||
+ | ** [http://www.phas.ubc.ca/~mce/mcedocs/overview/MEC-C580-154_48HP_Subrack_Dimensions MCE 48-HP Dimenstions (PDF)] | ||
Note: HP is a unit of length [http://en.wikipedia.org/wiki/Horizontal_pitch ] | Note: HP is a unit of length [http://en.wikipedia.org/wiki/Horizontal_pitch ] | ||
Line 30: | Line 34: | ||
== Other information == | == Other information == | ||
* [[MCE Power Requirements]] | * [[MCE Power Requirements]] | ||
− | * [http://www.phas.ubc.ca/~mce/mcedocs/overview/SC2_ELE_S580_005_Rev4.0_mce_interfaces.pdf Hardware Interface (PDF)] (SC2_ELE_S580_005) | + | * [http://www.phas.ubc.ca/~mce/mcedocs/overview/SC2_ELE_S580_005_Rev4.0_mce_interfaces.pdf Hardware Interface Block Diagram(PDF)] (SC2_ELE_S580_005) |
* [http://www.phas.ubc.ca/%7Emce/mcedocs/hardware/SC2_MEC-S580-504%20Subrack%20Mounting.doc Subrack Mounting Instructions (DOC)] (SC2-MEC-S580-504) | * [http://www.phas.ubc.ca/%7Emce/mcedocs/hardware/SC2_MEC-S580-504%20Subrack%20Mounting.doc Subrack Mounting Instructions (DOC)] (SC2-MEC-S580-504) | ||
* [[MCE Maintenance|Hardware Maintenance notes]] | * [[MCE Maintenance|Hardware Maintenance notes]] | ||
[[Category:Hardware]] | [[Category:Hardware]] |
Revision as of 12:01, 28 November 2012
Template:Hierarchy header Two types of MCE subracks are in production:
- a large (72-HP) subrack containing 5 MDM connectors and four read-out cards.
- a small (48-HP) subrack containing 3 MDM connectors and two read-out cards.
An intermediate sized 60-HP subrack was also prototyped but not produced in large numbers. Functionally it is equivalent to the modern 48-HP subrack.
Components
A fully-kitted subrack contains:
- 1 clock card
- 2 (48-HP subrack) or 4 (72-HP subrack) readout cards (fewer are installed if the extra read-out capacity is not needed)
- 3 bias cards (in some situations one might be removed)
- 1 address card
It also contains the following which are generally not "user-replaceable":
- 1 bus backplane
- 1 instrument backplane
- 3 (48-HP subrack) or 5 (72-HP subrack) MDM filter boxes
- Notes
- before the development of fast bias cards, in each subrack, one bias card was often replaced with a biasing address card (BAC), to allow for fast SQ2 switching. Modern bias cards can now perform fast switching and the BAC option is now obsolete.
- the 72-HP subrack also has space for a power supply (PSA) which is now obsolete and no longer installed. See MCE Power Requirements for current subrack power options
Dimensions and Weight
- A fully populated 3-MDM MCE weighs 9.5 kg
- Dimensions for a 48-HP MCE: ~ 40cm x 31cm x 34cm (L x W x H)
Note: HP is a unit of length [1]
Other information
- MCE Power Requirements
- Hardware Interface Block Diagram(PDF) (SC2_ELE_S580_005)
- Subrack Mounting Instructions (DOC) (SC2-MEC-S580-504)
- Hardware Maintenance notes