Difference between revisions of "MCE Cooling for balloon-based experiments"
From MCEWiki
(One intermediate revision by the same user not shown) | |||
Line 4: | Line 4: | ||
[[File:2014-10-24_48HP_Subrack_with_cooling_(M12-017).PNG |thumb |left|snapshot of the solidworks model ]] | [[File:2014-10-24_48HP_Subrack_with_cooling_(M12-017).PNG |thumb |left|snapshot of the solidworks model ]] | ||
+ | |||
+ | [[Category:Subrack]] |
Latest revision as of 16:15, 31 August 2016
We have built a passive cooling system for the MCEs used in balloon-based experiments. Fins are inserted between the cards and heat transported from the fins to a heat-extraction flange via heat pipes. On the Spider gondola, the heat-extraction flange is bolted directly to the cryostat wall, which provides a sufficiently large radiating surface to cool its (48 HP) subracks.
Here are some pictures of MCE flight hardware