Difference between revisions of "Vicor Power Assembly"
From MCEWiki
 (→Photos)  | 
				|||
| Line 1: | Line 1: | ||
{{Hierarchy header}}  | {{Hierarchy header}}  | ||
| − | The MCE can   | + | The MCE can be equipped with a 18–36Vin (24Vin nominal) switching supply designed for use in balloon-based experiments. This unit contains a set of [http://www.vicorpower.com/dc-dc-converters-board-mount Vicor DC-DC converters] that are trimmed to accomodate losses of up to 2m cable, so they can be located up to 2m away from the actual MCE crate.  | 
== Specification==  | == Specification==  | ||
| Line 38: | Line 38: | ||
#The Vicor supply is equipped with two Winchester connectors to power two MCE48 crates. So far, we are able to use a Y cable and power two MCE48 from one connector. When we tried to use each connector separately, with separate cables, oddly enough, the noise performance was degraded.  | #The Vicor supply is equipped with two Winchester connectors to power two MCE48 crates. So far, we are able to use a Y cable and power two MCE48 from one connector. When we tried to use each connector separately, with separate cables, oddly enough, the noise performance was degraded.  | ||
# We have not used the Vicor supply to power a 5-MDM MCE72 '''yet'''. The power requirements for a 5-MDM MCE are disctributed slightly differently than twice an MCE48 mainly due to LN_BIAS circutries.  | # We have not used the Vicor supply to power a 5-MDM MCE72 '''yet'''. The power requirements for a 5-MDM MCE are disctributed slightly differently than twice an MCE48 mainly due to LN_BIAS circutries.  | ||
| + | |||
| + | == Cooling ==  | ||
| + | For Spider, the mounting/heat extraction block is bolted to a heat exchanger through which the <sup>4</sup>He blow-off from the cryostat's vapour-cooled shield is vented.  | ||
== Photos ==  | == Photos ==  | ||
<gallery>  | <gallery>  | ||
Revision as of 14:10, 28 February 2014
Template:Hierarchy header The MCE can be equipped with a 18–36Vin (24Vin nominal) switching supply designed for use in balloon-based experiments. This unit contains a set of Vicor DC-DC converters that are trimmed to accomodate losses of up to 2m cable, so they can be located up to 2m away from the actual MCE crate.
Contents
Specification
- DC Input Type
 - 18-36V
 - 3A from 24V to power one 3-MDM MCE48 crate (6A for two)
 
- DC output
 - pVa: 6.1 to 6.3 V
 - nVa: -6.1 to -6.3 V
 - Vlvd: 4.4 to 4.7 V
 - Vcore: 2.9 to 3.2 V
 
- Watts
 - 100W
 
- Regulated
 - Yes
 
- Efficiency
 - 75%
 - Dimensions (L x W x H)
 - 24cm x 20cm x 5cm
 - Weight
 - < 2kg and a 1m power cable is ~1kg
 
Schematics
- Schematics for the Vicor Supplies can be found here
 - The schematics for the Wiring harness in the box and the pinout for the Winchester connector: pdf
 
Check the schematics for Input/Output connector pinout.
- Output Connector
 - Winchester MRA34SG
 - Input Connector
 - Amphenol PTC-2A-14-5P
 
Mechanical Drawings
Mechanical Drawings for Vicor Aluminum Box RevC
Notes
- The Vicor supply is equipped with two Winchester connectors to power two MCE48 crates. So far, we are able to use a Y cable and power two MCE48 from one connector. When we tried to use each connector separately, with separate cables, oddly enough, the noise performance was degraded.
 - We have not used the Vicor supply to power a 5-MDM MCE72 yet. The power requirements for a 5-MDM MCE are disctributed slightly differently than twice an MCE48 mainly due to LN_BIAS circutries.
 
Cooling
For Spider, the mounting/heat extraction block is bolted to a heat exchanger through which the 4He blow-off from the cryostat's vapour-cooled shield is vented.